make purge-osd interactive with preflight checks and step-by-step prompt - #455
taraasrita10 wants to merge 1 commit into
Conversation
subhamkrai
left a comment
There was a problem hiding this comment.
Can you also, share your testing result or SS of output?
| _, err := strconv.Atoi(osdID) | ||
| // selectUnhealthyOSD queries ceph for all down OSDs and prompts the user to pick one. | ||
| // Exits if the cluster cannot be reached or no unhealthy OSDs are found. | ||
| func selectUnhealthyOSD(ctx context.Context, clientsets *k8sutil.Clientsets, operatorNS, storageNS string) int { |
There was a problem hiding this comment.
Let's move all the implementation details under pkg/, it could be new under ``pkg/ceph/osd_purge.go
| clientsets := root.ClientSets | ||
| operatorNS := root.OperatorNamespace | ||
| storageNS := root.StorageClusterNamespace |
There was a problem hiding this comment.
| clientsets := root.ClientSets | |
| operatorNS := root.OperatorNamespace | |
| storageNS := root.StorageClusterNamespace |
we can directly use root.* any reason for above change?
| if details.pvcName != "" { | ||
| fmt.Printf("PVC %q is now Pending (awaiting disk).\n", details.pvcName) | ||
| } | ||
| fmt.Println("\nNext steps:") |
There was a problem hiding this comment.
| fmt.Println("\nNext steps:") | |
| fmt.Println("Next steps:") |
instead of \n can we use Println so that we can avoid \n
| fmt.Printf("PVC %q is now Pending (awaiting disk).\n", details.pvcName) | ||
| } | ||
| fmt.Println("\nNext steps:") | ||
| fmt.Println(" Replace the physical disk and scale the LSO operator back up.") |
There was a problem hiding this comment.
| fmt.Println(" Replace the physical disk and scale the LSO operator back up.") | |
| fmt.Println("Replace the physical disk and scale the LSO operator back up.") |
| } | ||
|
|
||
| if len(unhealthy) == 0 { | ||
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found")) |
There was a problem hiding this comment.
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found")) | |
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found to be purged")) |
| logging.Fatal(fmt.Errorf("invalid selection")) | ||
| } | ||
|
|
||
| return unhealthy[choice-1].OSD |
There was a problem hiding this comment.
| return unhealthy[choice-1].OSD | |
| return unhealthy[choice1].OSD |
Is '- 1 ' before the OSD ID?
There was a problem hiding this comment.
The index into the unhealthy slice is not related to the OSD ID. Don't you just want to return the OSD ID? Also, you need to confirm that the ID is in the unhealthy slice.
| return unhealthy[choice-1].OSD | |
| return choice |
There was a problem hiding this comment.
choice is the index, not the ID. Therefore return unhealthy[choice-1].OSD would return the OSD ID. The user is prompted to enter the index according to the listed unhealthy OSDs, not the OSD ID. But I think it would be better if they were prompted to enter the ID. Will make that change.
| // checkLSOScaledDown verifies that the LSO operator is scaled down before purging. | ||
| // If LSO is running, it could reprovision the disk we are about to wipe. | ||
| // Returns false if LSO is running or its status cannot be verified. | ||
| func checkLSOScaledDown(ctx context.Context, clientsets *k8sutil.Clientsets) bool { |
There was a problem hiding this comment.
Users need to scale down the LSO, right? We are not scalling it down ourself.
There was a problem hiding this comment.
Yes, the users need to scale it down. We would just be verifying if it has been scaled down. If not, we'd stop the purge and ask the user to scale it down, and exit.
|
|
||
| // clusterHealthCheck runs `ceph health detail` and prompts the user if the cluster | ||
| // is not healthy. Returns false if the user chooses to cancel. | ||
| func clusterHealthCheck(ctx context.Context, clientsets *k8sutil.Clientsets, operatorNS, storageNS string) bool { |
There was a problem hiding this comment.
We should having something in rook to ceph health see if we can use existing method if not we can have the current change.
There was a problem hiding this comment.
Found IsCephHealthy in Rook, but it returns a boolean. We need the health err/warning to display it to the user so that they can decide whether to proceed with the purge.
| if _, err := clientsets.Kube.AppsV1().Deployments(storageNS).Update(ctx, deployment, metav1.UpdateOptions{}); err != nil { | ||
| logging.Fatal(fmt.Errorf("failed to stop OSD deployment %q: %v", details.deploymentName, err)) | ||
| } | ||
| fmt.Printf("Stopped osd.%d process.\n", details.id) |
There was a problem hiding this comment.
| fmt.Printf("Stopped osd.%d process.\n", details.id) | |
| Logger.Info("Stopped osd.%d process.\n", details.id) |
| } | ||
|
|
||
| if len(unhealthy) == 0 { | ||
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found")) |
There was a problem hiding this comment.
We need to be clear in the error message how they can force an OSD to be unhealthy so they can proceed to remove it if desired.
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found")) | |
| logging.Fatal(fmt.Errorf("no unhealthy OSDs found to be purgred, to force remove an OSD that is running, first scale down the OSD deployment. ")) |
| logging.Fatal(fmt.Errorf("invalid selection")) | ||
| } | ||
|
|
||
| return unhealthy[choice-1].OSD |
There was a problem hiding this comment.
The index into the unhealthy slice is not related to the OSD ID. Don't you just want to return the OSD ID? Also, you need to confirm that the ID is in the unhealthy slice.
| return unhealthy[choice-1].OSD | |
| return choice |
| lsoNS := "openshift-local-storage" | ||
| deployment, err := clientsets.Kube.AppsV1().Deployments(lsoNS).Get(ctx, "local-storage-operator", metav1.GetOptions{}) | ||
| if err != nil { | ||
| logging.Warning("could not verify LSO operator status: %v. Scale it down before running this command.", err) |
There was a problem hiding this comment.
Why exactly does the LSO operator need to be scaled down? Does it only need to be scaled down while we are running this cleanup operation? If so, perhaps we offer to scale it down before we start, and scale it up when we are done. But if there is some other side effect like re-provisioning the same volume after it is clean, the user would need clear instructions to decide when to scale it back up.
There was a problem hiding this comment.
We are scaling the LSO operator down only during the cleanup operation because if not scaled down, the disk being wiped would get re-provisioned again.
We're not offering to scale it down because -
- The operator can be scaled back up only after the disk has been replaced. The time taken for that is not definite.
- The user would be instructed to scale the operator down, then run the command. Upon success, the command exits with instructions about when and how to scale the LSO operator back up. Incase the user would like to replace the disk, they can scale it back up after replacing it. Incase they would like to redeploy the same disk, then they can scale it back up as soon as the purge is complete and the command exits.
| logging.Fatal(fmt.Errorf("could not determine node for osd.%d: PV %q has no node affinity", osdID, details.pvName)) | ||
| } | ||
|
|
||
| fmt.Printf("\nOSD Details:\n") |
There was a problem hiding this comment.
Is this duplicate for what is printed by printDryRun()?
There was a problem hiding this comment.
Yes, I have removed it now.
| if _, err := clientsets.Kube.AppsV1().Deployments(storageNS).Update(ctx, deployment, metav1.UpdateOptions{}); err != nil { | ||
| logging.Fatal(fmt.Errorf("failed to stop OSD deployment %q: %v", details.deploymentName, err)) | ||
| } | ||
| fmt.Printf("Stopped osd.%d process.\n", details.id) |
There was a problem hiding this comment.
The OSD pod might not actually be stopped at this point. The pod could take a few seconds to scale down, so we should wait for it.
| // If yes: polls safeToDestroy every 15 seconds with Ctrl+C support for graceful exit. | ||
| // If no: returns true so the caller passes force=true to the purge. | ||
| func dataMigrationPrompt(ctx context.Context, clientsets *k8sutil.Clientsets, operatorNS, storageNS, osdIDStr string, osdID int) bool { | ||
| if !promptYN("Wait for data migration to complete?") { |
There was a problem hiding this comment.
We need more details in the question. What data migration is in progress? Do we know data migration is in progress? If PGs are already active+clean, then we don't need this prompt either.
There was a problem hiding this comment.
I've added more details to the question. The data migration in question is the one that happens when an OSD is marked out, and data is migrated from the OSD to other nodes. I've also added a ceph status check, which sets force=true when PGs are in an active+clean state (and the safeToDestroy check is failing). In case they are not in active+clean, then the user is prompted to approve skipping data migration.
|
[APPROVALNOTIFIER] This PR is NOT APPROVED This pull-request has been approved by: taraasrita10 The full list of commands accepted by this bot can be found here. DetailsNeeds approval from an approver in each of these files:Approvers can indicate their approval by writing |
…mpts This change replaces the existing purge-osd command with a fully interactive process that walks the user through each step of OSD removal. The user is prompted to choose the OSD to purge, check current cluster health, collect the details of resources to be deleted, stop the osd, mark it out, wait for data migration, check if the osd is safe to destroy and affirm the purge. After the purge takes place, the user is guided to scale the LSO operator back up after disk replacement. Signed-off-by: Prabhala Tara Aasrita <taraprabhala@ibm.com>
3f05535 to
f8242de
Compare
|
@subhamkrai @travisn I've made the suggested changes, PTAL. Thanks! |
travisn
left a comment
There was a problem hiding this comment.
Can you also, share your testing result or SS of output?
As Subham requested, please share the output of a test run, to see what the flow looks like from the user's perspective. This can help see what to refine for user clarity.
| PreRunE: validateOsdID, | ||
| Use: "purge-osd", | ||
| Short: "Permanently remove an OSD from the cluster.", | ||
| Long: `Safely remove an OSD from the cluster with interactive prompts. |
There was a problem hiding this comment.
@subhamkrai Such a detailed long description is not expected, right?
| } | ||
| } | ||
| logging.Fatal(fmt.Errorf("OSD %d is not unhealthy. Only down OSDs can be purged.", osdID)) | ||
| return -1 |
| // Returns false if LSO is running or its status cannot be verified. | ||
| func CheckLSOScaledDown(ctx context.Context, clientsets *k8sutil.Clientsets) bool { | ||
| lsoNS := "openshift-local-storage" | ||
| deployment, err := clientsets.Kube.AppsV1().Deployments(lsoNS).Get(ctx, "local-storage-operator", metav1.GetOptions{}) |
There was a problem hiding this comment.
Is there a way to override this requirement? It doesn't seem strictly necessary to stop the LSO operator before continuing to purge the OSD.
| return true | ||
| } | ||
|
|
||
| logging.Warning("%s", out) |
There was a problem hiding this comment.
What warning is this going to print? We may need to give more context that helps them decide if they want to continue.
| fmt.Println() | ||
| fmt.Println("Next steps:") | ||
| fmt.Println("Replace the physical disk and scale the LSO operator back up.") | ||
| fmt.Println("If reusing the same disk: scale the LSO operator back up.") |
There was a problem hiding this comment.
If they want to re-use the same disk, seems like we should give them the option in the first place to not stop the LSO operator.
| return true | ||
| } | ||
|
|
||
| if !PromptYN("The OSD process is currently running. Stop it before proceeding?") { |
There was a problem hiding this comment.
| if !PromptYN("The OSD process is currently running. Stop it before proceeding?") { | |
| if !PromptYN("The OSD pod is currently running. Stop it before proceeding?") { |
|
|
||
| // Wait for pod to actually terminate | ||
| logging.Info("Waiting for OSD pod to terminate...") | ||
| deadline := time.Now().Add(1 * time.Minute) |
There was a problem hiding this comment.
Always use UTC time in code to avoid any issues with time zones, daylight savings, etc.
| deadline := time.Now().Add(1 * time.Minute) | |
| deadline := time.Now().UTC().Add(1 * time.Minute) |
| for { | ||
| select { | ||
| case <-sigCh: | ||
| fmt.Printf("\nosd.%d is marked out. Re-run this command to resume the purge.\n", osdID) |
There was a problem hiding this comment.
This signal indicates that the CLI tool was canceled, not that the OSD was marked out, right? This message seems wrong.
This change replaces the existing purge-osd command with a fully interactive process that walks the user through each step of OSD removal with pre-flight checks and step-by-step prompts.
The following steps take place as a part of the interactive purge flow -
selectUnhealthyOSD) - Scans the cluster for down OSDs and presents a list to the user, who picks the OSD to be purged interactively instead of passing it as an argument.checkLSOScaledDown) - Verifies the LSO operator is scaled down before proceeding.clusterHealthCheck) - Checks cluster health before purge. If the cluster is not healthy, the output is shown and user is prompted to confirm before continuing.gatherOSDDetails) - Queries the OSD deployment, PVC, and PV from k8s to collect the host name, PVC/PV names, device path and encryption state before deletion begins and to show the user a summary of resources being removed.stopOSDIfRunning) - Scales the OSD deployment to 0. Skips if already at 0.markOSDOut) - Marks the OSD out and triggers data migration. Skips if already marked out from a previous run.dataMigrationPrompt) - Prompts to wait for data migration. If yes, pollssafeToDestroyevery 15 seconds till it returns true (incase of an exit, prints a resume message as the previous steps are idempotent). If no, sets force=true so Rook skips the safeToDestroy check internally.printDryRun): Lists all k8s and Ceph resources that will be deleted (deployment, PVC, PV, DM crypt mapping, device) before the final confirmation prompt.rook.PurgeOsds. On success, prints the PVC pending status and instructions for scaling LSO back up after disk replacement.