Skip to content

About

LP-Research LPMS inertial measurement units in ossia score, through OpenZen

Resources

Code of conduct

Contributing

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

score-addon-openzen

Access LP-Research LPMS inertial measurement units from ossia score, through OpenZen.

Serial/USB works everywhere; classic Bluetooth is built in when the platform Bluetooth development files are present.

Building

git submodule update --init --recursive

Then drop the folder into score/src/addons and configure score as usual.

Design notes

One shared backend, no thread per sensor

Everything goes through a single ossia::openzen::manager (OpenZen/Manager.hpp), following the same shape as libossia's joystick protocol manager:

  • One backend thread, shared by every sensor, owns every call that can block. obtainSensor() alone can take several seconds - OpenZen probes baud rates with a 2s IO timeout and retries - so it must never be reached from the GUI or the network thread.
  • No data thread at all. The measurement event queue is drained by an ossia::timer on each registered network context, so samples are delivered on the thread ossia already wants parameter updates on, and adding a seventeenth IMU adds no threads.

Two ZenClients are used: one whose queue carries measurement data and is drained by the pump, and one that only carries device listings and is drained by the backend thread. That way discovery never has to be routed across threads.

push() may be reached from the audio thread, so control writes are only ever enqueued, never executed inline.

Surviving a replug

OpenZen does not detect disconnection. ZenEventType_SensorDisconnected is only emitted from Sensor::~Sensor, that is, when we release the sensor. When a cable is pulled, PosixDeviceInterfaceImpl::run() returns from its IO thread and nothing else happens: the sensor object stays alive and simply goes quiet forever.

So silence is the disconnection signal. A watchdog on the backend thread (default 500 ms, configurable) declares the link dead, releases the port and starts looking for the sensor again. This also covers what no IO error would report anyway - a brown-out, a wedged firmware, an RF dropout on Bluetooth.

The node tree is built once and never torn down. A sensor that is not present sits at /connected = false with the rest of the tree intact, so every cable drawn against it in a score survives the cable being pulled - and a document opens with its full tree whether or not the hardware is there.

On reconnection the whole configuration is pushed onto the sensor again, so what the document says is always what the hardware ends up doing, whatever was left in its flash.

Finding the sensor again

Matching is by serial number where possible, since that is what survives the sensor coming back on a different port:

  1. A listing entry that advertises our serial number. On Linux the SiLabs USB serial string is in sysfs and OpenZen re-resolves the tty from it on every connection, so /dev/ttyUSB0 becoming /dev/ttyUSB1 is a non-event.
  2. Otherwise the port it was last seen on.
  3. Otherwise - a plain Windows COM port carries no identity at all - the remaining ports are tried and the serial number is verified over the wire once connected.

Measurements are detected, not configured

Nothing about what a unit measures has to be picked by hand. On connection the sensor's ZenImuProperty_Output* flags are read back and a node is created for each measurement it actually produces - so a unit with a magnetometer gets /imu/mag, one without simply does not, and a GNSS component brings /gnss/* with it.

Node creation is additive: a node is never removed once it exists. Unplugging a sensor, or reconnecting one that has been reconfigured in the meantime, leaves every cable drawn against it intact. The tree is saved with the document, so a score reopens with its full namespace whether or not the hardware is present.

Which property gates which field depends on the firmware family, and getting it wrong changes the frame length rather than merely enabling the wrong value: the legacy firmware derives the calibrated vector host-side from the raw one behind a single flag, IG1 gates them separately, and the LPMS-BE1 reports its only gyro in the second slot. See manager::read_capabilities and manager::apply_outputs.

Bandwidth

Turning off measurements is still available, behind "Detect measurements from the sensor". These map to the same ZenImuProperty_Output* flags: every measurement enabled takes room in the frame the sensor puts on the wire, and at a fixed baud rate that is what decides the sample rate that can be reached.

Serial port permissions on Linux

/dev/ttyUSB* usually belongs to a group (uucp, dialout depending on the distribution) that a user is not in by default, and the sensor will sit in failed with a message saying so. Fix it once with:

sudo usermod -aG uucp $USER   # or dialout

then log out and back in.

Baud rate

The rate a unit runs at is whatever was last written to its flash, and no IO system can report it before connecting: OpenZen assumes a default and gives up when that is wrong. 921600 is the LPMS factory default while OpenZen's Linux backend assumes 115200, so any fixed guess is wrong for some sensor. The backend therefore probes, one rate per attempt so that a sensor working through the list does not monopolise the thread every other sensor shares, and remembers what worked so reconnection is immediate.

The sampling rate is left alone by default for the same reason: sensors accept only a fixed set of rates and answer the rest with a NACK, and losing a working link over a preference is the wrong trade. Setting one that the sensor refuses is reported and otherwise ignored.

Testing

cmake . -DSCORE_ADDON_OPENZEN_TESTS=1
cmake --build . --target score_addon_openzen_tests
./score_addon_openzen_tests            # everything
./score_addon_openzen_tests "~[hardware]"   # only what needs no sensor
./score_addon_openzen_tests "[hardware]"    # only what does
  • tests/test_mapping.cpp covers the pure functions - axis conventions, identity, baud ordering, the additive capability merge. These are where a silent mistake produces plausible-looking but wrong numbers, so they are tested against hand-worked values.
  • tests/test_backend.cpp runs the real backend. The cases tagged [hardware] are skipped when no sensor is attached; the rest cover the paths that must hold when nothing is plugged in, which is the normal state of affairs while a score is being written.

ctest runs the no-hardware subset. There is also score_addon_openzen_smoke, a standalone harness that prints a readable trace and pauses so the cable can be pulled to watch the watchdog fire - useful when bringing up a new sensor, not something for CI.

Add -DSCORE_ADDON_OPENZEN_VERBOSE=1 to log every frame exchanged with the sensor; that is how the CURS3 problems above were found.